Index:

GeneSeq PLUS, TTR

Order Name GeneSeq P/TTR
Test Number: 5194961
Revision Date 03/21/2023
Test Name Methodology LOINC Code
GeneSeq PLUS, TTR
Polymerase Chain Reaction  
SPECIMEN REQUIREMENTS
Specimen Specimen Volume (min) Specimen Type Specimen Container Transport Environment
Preferred 5 mL (3 mL) Whole Blood ACD Solution A or B (Yellow Top) Room Temperature
Alternate 1 5 mL (3 mL) Whole Blood EDTA (Lavender Top) Room Temperature
Alternate 2 1 Saliva Oragene Dx saliva kit Room Temperature
Alternate 3 1 Buccal swab Buccal swab in UTM Room Temperature
Instructions Specimen Type: Whole blood or PurFlock buccal swab kit or Oragene Dx saliva kit
Specimen Volume: 8.5 mL whole blood or PurFlock buccal swab kit or Oragene Dx saliva kit
Mininum Volume: 3 mL whole blood or PurFlock buccal swab kit or Oragene Dx saliva kit
Collection: Standard phlebotomy. Follow PurFlock buccal swab kit or Oragene Dx 500 saliva kit collection instructions. Do not eat, drink, smoke, or chew gum 30 min prior to collection.
Specimen Storage: Maintain specimen at room temperature or refrigerate at 4C Do not freeze.
Special Instructions: In cases in which there is a known variant documented in the family, the physician may prefer to order Targeted Variant Analysis, test code 5194970. Test orders must include an attestation that the provider has the patient's informed consent for genetic testing.
GENERAL INFORMATION
Expected TAT 14 - 21 days In some cases, additional time may be required for confirmatory or reflex tests.  
Clinical Use This test is used for diagnostic testing for transthyretin amyloidosis and presymptomatic testing for family members. Technologies used do not detect germline mosaicism and do not rule out the presence of large chromosomal aberrations including rearrangements and gene fusions, or variants in regions or genes not included in this test, or possible inter/intragenic interactions between variants or repeat expansions. Variant classification and/or interpretation may change over time if more information becomes available. False positive or false negative results may occur for reasons that include: rare genetic variants, sex chromosome abnormalities, pseudogene interference, blood transfusions, bone marrow transplantation, somatic or tissue-specific mosaicism, mislabeled samples or erroneous representation of family relationships. 
Performing Labcorp Test Code 482353 
Notes Labcorp Test Code: 482353
Lab Section Reference Lab