Rivaroxaban (Xarelto) Level
Order Name
Rivaroxaban
Test Number: 6905749
Revision Date 12/12/2022
Test Number: 6905749
Revision Date 12/12/2022
Test Name | Methodology | LOINC Code |
---|---|---|
Rivaroxaban (Xarelto) Level
|
Liquid Chromatography/Tandem Mass Spectrometry | 72624-0 |
SPECIMEN REQUIREMENTS | ||||
---|---|---|---|---|
Specimen | Specimen Volume (min) | Specimen Type | Specimen Container | Transport Environment |
Preferred | 1 mL (0.5 mL) | Plasma | Lithium Heparin PST (Light Green Top) | Room Temperature |
Alternate 1 | 1 mL (0.5 mL) | Plasma | Sodium Citrate 3.2% (Blue Top) | Room Temperature |
Alternate 2 | 1 mL (0.5 mL) | Plasma | EDTA (Lavender Top) | Room Temperature |
Instructions | Notes: 0.5 mL (Note: This volume Does NOT allow for repeat testing.) Specimen Type: Light blue-top (citrate) tube (preferred), lavender-top (EDTA) tube, or green-top (heparin) tube Specimen Storage: Room Temperature Specimen Collection: Transfer plasma to a plastic transport tube. Specimen Stability: Ambient: 7 days, Refrigerated : 14 days, Frozen: 14 days |
GENERAL INFORMATION | |
---|---|
Expected TAT | 5 - 7 days |
Performing Labcorp Test Code | 117050 |
Notes | Labcorp Test Code: 117050 |
CPT Code(s) | 80299 |
Lab Section | Reference Lab |