Sign In
Labcorp Oklahoma, Inc.
Test Directory


Index:

Anti-Mullerian Hormone

Order Name AMH
Test Number: 5570915
Revision Date 01/02/2024
Test Name Methodology LOINC Code
Anti-Mullerian Hormone
Chemiluminescence Assay 38476-8 
SPECIMEN REQUIREMENTS
Specimen Specimen Volume (min) Specimen Type Specimen Container Transport Environment
Preferred 1 mL (0.5 mL) Serum Clot Activator (Red Top, No-Gel) Refrigerated
Alternate 1 1 mL (0.5 mL) Serum Clot Activator SST Refrigerated
Alternate 2 1 mL (0.5 mL) Plasma Lithium Heparin PST (Green/Gray Top) Refrigerated
Instructions Allow serum to clot then Separate from cells ASAP or within 2 hours of collection.  
Unacceptable Conditions: Hemolyzed or lipemic specimens.
Stability: Ambient: 1 day; Refrigerated: 6 days; Frozen: >6 days (avoid repeated freeze/thaw cycles)
GENERAL INFORMATION
Testing Schedule Mon, Wed, Fri 
Expected TAT 2-4 Days  
CPT Code(s) 82166
Lab Section Chemistry