Sign In
Labcorp Oklahoma, Inc.
Test Directory


Index:

Legionella pneumophila/Culture/Stain

Order Name C LEGIO C/S
Test Number: 6101800
Revision Date 04/29/2024
Test Name Methodology LOINC Code
[6101800] Legionella Culture
Culture 89594-6 
[5195274] Legionella DFA
Direct Fluorescent Antibody 88585-5 
[5195276] Legionella Result 1
Possible Result  
[5195277] Legionella Result 2
Possible Result  
[5195278] Legionella Result 3
Possible Result  
[5195279] Legionella Result 4
Possible Result  
[5195280] Legionella Antimicrobial Susceptibility
Possible Result  
Legionella Source (AOE Code 5195275)
Prompt  
SPECIMEN REQUIREMENTS
Specimen Specimen Volume (min) Specimen Type Specimen Container Transport Environment
Preferred 5 mL (1 mL) Bronchial lavage/wash Sterile Screwtop Container Refrigerated
Alternate 1 See Instructions Respiratory specimen Sterile Screwtop Container Refrigerated
Alternate 2 1 mL (1 mL) Lung Biopsy Sterile Screwtop Container Frozen
Instructions Specimen: Lung tissue, Transtracheal aspirate, Pleural fluid, Bronchoalveolar lavage (BAL) fluid, Sputum
Volume: 1 mL lung biopsy (frozen), transtracheal aspirate, pleural fluid; 5 mL bronchoalveolar lavage (BAL) fluid; 5 mL sputum
Minimum Volume: 1 mL fluid (Note: This volume does not allow for repeat testing.)
Container: Sterile Screwtop Container
Storage Instructions: Maintain specimen at Refrigerated at  2°C to 8°C.
Causes for Rejection: Swab specimen; inappropriate specimen transport device; unlabeled specimen or name discrepancy between specimen and request label; specimen received after prolonged delay (usually more than 72 hours); specimen received in expired transport; environmental water samples such as air conditioning/cooling towers
GENERAL INFORMATION
Expected TAT 7 - 16 days  
Clinical Use Detects Legionella sp. in respiratory specimens. Sensitivity is not as good as the urinary antigen test. We highly recommend LEGION AGU as a superior test. 
Performing Labcorp Test Code 188227 
CPT Code(s) 87070, 87278
Lab Section Reference Lab