Lupus Anticoagulant-Hexagonal Phospholipid Neutralization
Order Name
HEXA PHOS
Test Number: 1507375
Revision Date 10/08/2024
Test Number: 1507375
Revision Date 10/08/2024
Test Name | Methodology | LOINC Code |
---|---|---|
Lupus Anticoagulant-Hexagonal Phospholipid Neutralization
|
Clot Detection | 33930-9 |
SPECIMEN REQUIREMENTS | ||||
---|---|---|---|---|
Specimen | Specimen Volume (min) | Specimen Type | Specimen Container | Transport Environment |
Preferred | 5.4 mL | Whole Blood | Sodium Citrate 3.2% (Blue Top) | Room Temperature |
Alternate 1 | 3.0 mL | Double Spun Plasma | Sterile, Capped Plastic Tube | Frozen |
Instructions | Please indicate anticoagulant therapy. Collect Two 2.7mL Sodium Citrate 3.2% (Blue Top) tubes. Each 2.7mL Sodium Citrate 3.2% (Blue Top) tube must be filled to the proper level, no hemolysis. Improperly filled tubes can give erroneous results. Whole blood must be transported to lab immediately. If testing cannot be started within 4 hours of collection the specimen must be double spun then 1.5mL plasma aliquot from each tube into individual plastic aliquot tubes and freeze. Do not pool aliquots together! |
GENERAL INFORMATION | |
---|---|
Testing Schedule | Fri |
Expected TAT | 1-7 Days |
CPT Code(s) | 85598 |
Lab Section | Coagulation |